Product Description
Our Open Loop Hall Sensors are also known as Hall magnetic balance current sensors, they are magnetic sensors that measure AC and DC currents and provide electrical isolation between the circuit under test and the sensor output. And they can also detect the strength and direction of a magnetic field generated by a permanent magnet or electromagnet, with the output varying proportionally to the strength of the magnetic field being detected. Due to their outstanding performance, they are widely used in electrical measurement, automatic control and in dispatching systems in the power, petroleum and railway sectors.
Features
Our Open Loop Hall Sensors provide output voltage proportional to current without the use of feedback control. Their compact size and low power consumption in use make them very popular in circuit applications. They are very simple to use and easy to install and remove, they are also much cheaper than other types of sensors, do not require much maintenance, save you energy and money, and are very stable in operation and have good accuracy when used with related equipment.
Appearance

AHBC-LT1005

AHBC-LF

AHBC-LTA
Dimensions

Fig.1

Fig.2
|
Size Specification |
Outline size(mm) |
Through size(mm) |
Mounting |
Figure |
|||||
|
W |
H |
D |
a |
e |
Φ |
M |
N |
||
|
AHKC-E |
53 |
72 |
16 |
/ |
/ |
21 |
47 |
/ |
Fig.1 |
|
AHKC-LT |
90 |
73.5 |
25 |
/ |
/ |
32.5 |
74.5 |
71 |
Fig.1 |
|
AHKC-BS |
43 |
32.5 |
19 |
20.5 |
10.5 |
/ |
/ |
/ |
Fig.2 |
|
AHKC-BSA |
43 |
32.5 |
19 |
20.5 |
10.5 |
/ |
/ |
/ |
Fig.2 |
|
AHKC-F |
74 |
57 |
22 |
43 |
13 |
/ |
/ |
22 |
Fig.2 |
|
AHKC-FA |
94 |
60.5 |
26.5 |
52 |
15 |
/ |
83 |
28 |
Fig.2 |
|
AHKC-HAT |
94 |
76.5 |
24 |
52.5 |
32 |
/ |
83 |
28 |
Fig.2 |
Current Ratio
|
|
Specification |
Rated current |
Power supply |
Rated output |
Measuring aperture (mm) |
Precisio n degree |
|
AHKC-E |
0~(20-500)A |
±15V |
5V |
φ 20 |
1 |
|
|
AHKC-LT |
0~(100-800)A |
±15V |
5V |
φ 32.5 |
1 |
|
|
AHKC-BS |
0~(20-500)A |
±15V |
5V |
20.5*10.5 |
1 |
|
|
AHKC-BSA |
DC 0~(50-500)A |
12V/15V/24 V |
4~20mA |
20.5*10.5 |
1 |
|
|
AHKC-F |
0~(200-1000)A |
±15V |
5V |
43*13 |
1 |
|
|
AHKC-FA |
0~(200-1500)A |
±15V |
5V |
52*15 |
1 |
|
|
AHKC-HAT |
0~(400-2000)A |
±15V |
5V |
52*32 |
1 |
Note: Rated current unlabeled indicates that AC and DC input current can be measured, please specify when ordering.
Wiring
● Definition of wiring terminals

● Definition of wiring terminals

Quotation