Production Description
Hall current sensors are mainly used to isolate and convert AC, DC, pulse and other complex signals. After signal control of current signals are converted according to the Hall Effect Theory, they can be directly acquired by AD, DSP, PLC, secondary instruments and other devices.
Hall current sensors are widely applicable for acquisition and feedback in the current monitoring, battery application, inverter, solar power management, direct current cabinet, DC motor drive, electroplating, welding, frequency converter, UPS servo control systems. They feature quick response, a wide range of measurements, high precision, strong overload capacity, good linearity and excellent anti-interference performance.
Appearance




Parameter
Technical parameters |
Data |
|||
Split/closed open-loop |
Hall (true RMS) |
|||
Output |
Nominal value |
Voltage: ±5V/±4V |
Current: 4-20mA |
|
Zero offset voltage (current) |
Voltage: ±20mV |
Current:±0.05mA |
||
Offset voltage (current) drift |
Voltage: ≤±1.0mV/℃ |
Current:±0.04mA/ ℃ |
||
Linearity |
≤0.2%FS |
|||
Power voltage |
DC±15V |
DC 24V |
||
Bandwidth |
0-20kHz |
|||
Response time |
≤5us |
≤1ms |
||
Dielectric strength |
Permissible 2500VAC between input/ output and power supply at the power frequency |
|||
Accuracy class |
1.0 |
|||
Ambient conditions |
Temperature |
Operating temperature:-25℃-+70℃; storage temperature: -40℃-+85℃ |
||
Humidity |
≤95%RH, no dew, no aggressive gas |
|||
Altitude |
≤3500m |
Dimensions
![]() |
![]() |
Fig.1 | Fig.2 |
Size Specification |
Outline size |
Through size |
Mounting size |
Figure |
|||||
W |
H |
D |
a |
e |
Φ |
M |
N |
||
AHKC-EKA |
60 |
64 |
16 |
/ |
/ |
20 |
47 |
/ |
Fig.1 |
AHKC-EKAA |
60 |
64 |
16 |
/ |
/ |
20 |
47 |
/ |
Fig.1 |
AHKC-EKDA |
60 |
64 |
16 |
/ |
/ |
20 |
47 |
/ |
Fig.1 |
AHKC-EKB |
100 |
102 |
24 |
/ |
/ |
40 |
80 |
/ |
Fig.1 |
AHKC-EKBA |
100 |
102 |
24 |
/ |
/ |
40 |
80 |
/ |
Fig.1 |
AHKC- |
100 |
102 |
24 |
/ |
/ |
40 |
80 |
/ |
Fig.1 |
AHKC-K |
127 |
63 |
25 |
64 |
16 |
/ |
/ |
30 |
Fig.2 |
AHKC-KAA |
127 |
63 |
25 |
64 |
16 |
/ |
/ |
30 |
Fig.2 |
AHKC-KDA |
127 |
63 |
25 |
64 |
16 |
/ |
/ |
30 |
Fig.2 |
AHKC-H |
149 |
79 |
25 |
82 |
32 |
/ |
/ |
46 |
Fig.2 |
AHKC-KA |
176 |
95.5 |
29 |
104 |
36 |
/ |
/ |
60 |
Fig.2 |
AHKC-HB |
204 |
111.5 |
29 |
132 |
52 |
/ |
/ |
48 × |
Fig.2 |
Current Ratio
![]() |
Specification |
Rated current |
Power supply |
Rated output |
Measuring aperture (mm) |
Precision degree |
AHKC-EKA |
0~(20-500)A |
±15V |
5V |
φ 20 |
1 |
|
AHKC-EKAA |
DC 0~(50-500)A |
12V/24V |
4~20mA |
φ 20 |
1 |
|
AHKC- EKDA |
AC 0~(50-500)A |
12V/24V |
4~20mA |
φ 20 |
1 |
|
AHKC-EKB |
0~(200-1000)A |
±15V |
5V |
φ 40 |
1 |
|
AHKC- EKBA |
DC 0~(200- 1000)A |
12V/24V |
4~20mA |
φ 40 |
1 |
![]() |
AHKC- EKBDA |
AC 0~(200~ 1000)A |
12V/24V |
4~20mA |
φ 40 |
1 |
AHKC-K |
0~(400-2000)A |
±15V |
5V |
64×16 |
1 |
|
AHKC- KAA |
DC 0~(400- 2000)A |
12V/24V |
4~20mA |
64×16 |
1 |
|
AHKC- KDA |
AC 0~(400- 2000)A |
12V/24V |
4~20mA |
64×16 |
1 |
|
AHKC-H |
0~(500-3000)A |
±15V |
5V |
82×32 |
1 |
|
AHKC-KA |
0~(500-5000)A |
±15V |
5V |
104×36 |
1 |
|
AHKC-HB |
0~(2000-20000)A |
±15V |
5V |
132×52 |
1 |
Note: Rated current unlabeled indicates that AC and DC input current can be measured, please specify when ordering.
Closed Hall Current Sensor
Fig.1
Fig.2
Size Specification |
Outline size(mm) |
Through size(mm) |
Mounting |
Figure |
|||||
W |
H |
D |
a |
e |
Φ |
M |
N |
||
AHKC-E |
53 |
72 |
16 |
/ |
/ |
21 |
47 |
/ |
Fig.1 |
AHKC-LT |
90 |
73.5 |
25 |
/ |
/ |
32.5 |
74.5 |
71 |
Fig.1 |
AHKC-BS |
43 |
32.5 |
19 |
20.5 |
10.5 |
/ |
/ |
/ |
Fig.2 |
AHKC-BSA |
43 |
32.5 |
19 |
20.5 |
10.5 |
/ |
/ |
/ |
Fig.2 |
AHKC-F |
74 |
57 |
22 |
43 |
13 |
/ |
/ |
22 |
Fig.2 |
AHKC-FA |
94 |
60.5 |
26.5 |
52 |
15 |
/ |
83 |
28 |
Fig.2 |
AHKC-HAT |
94 |
76.5 |
24 |
52.5 |
32 |
/ |
83 |
28 |
Fig.2 |
Current Ratio
|
Specification |
Rated current |
Power supply |
Rated output |
Measuring aperture (mm) |
Accuracy |
AHKC-E |
0~(20-500)A |
±15V |
5V |
φ 20 |
1 |
|
AHKC-LT |
0~(100-800)A |
±15V |
5V |
φ 32.5 |
1 |
|
AHKC-BS |
0~(20-500)A |
±15V |
5V |
20.5*10.5 |
1 |
|
AHKC-BSA |
DC 0~(50-500)A |
12V/15V/24 V |
4~20mA |
20.5*10.5 |
1 |
|
AHKC-F |
0~(200-1000)A |
±15V |
5V |
43*13 |
1 |
|
AHKC-FA |
0~(200-1500)A |
±15V |
5V |
52*15 |
1 |
|
AHKC-HAT |
0~(400-2000)A |
±15V |
5V |
52*32 |
1 |
Note: Rated current unlabeled indicates that AC and DC input current can be measured, please specify when ordering.
Quotation
Why choose us?
- We value our customers and strive to provide them with the highest level of satisfaction.
- We understand that the overall concept of Hall Effect Current Sensor must be firmly grasped in order for the enterprise to go to success and step into the international market.
- We are dedicated to providing exceptional customer service and support to all our customers.
- Equality and reciprocity are the premise of a trade agreement.
- We take pride in our commitment to excellence in all our products and services.
- We expect to become a model of a company where employees and the company develop together.
- We take pride in our attention to detail, ensuring that every sensor meets our stringent standards.
- Our determination to provide quality products reflects our highly responsible attitude to our customers and society, and is also the basic guarantee for sustainable development.
- Our Hall Effect Sensors are backed by a warranty, giving our customers peace of mind.