Closed Loop Hall Sensor

Closed Loop Hall Sensor

Closed-loop Hall current sensor is also called Hall magnetic balancing current sensor. It incorporates the mentioned theory with magnetic balancing theory. In other words, the ferromagnetic field concentrator concentrates the magnetic field generated by primary current and applies it to the Hall component.

Send Inquiry
  • Description
    manual(001)
    ce_WPS(001)
    CgAGfFpTIYaAMb--AAC3fhENYxU599(001)
    tuv_WPS(001)
    _WPS(001)

     

    Closed-loop Hall current sensor is also called Hall magnetic balancing current sensor. It incorporates the mentioned theory with magnetic balancing theory. In other words, the ferromagnetic field concentrator concentrates the magnetic field generated by primary current and applies it to the Hall component. Then the voltage signal output from Hall component is amplified and becomes the input of power amplifier. The offset current output flows through the secondary compensating coil. The magnetic field generated by secondary coil is opposite to the field generated by primary current. In such way, the primary field is compensated and the Hall output is reduced gradually. When the primary field is equivalent to the secondary one and the offset current keeps stable, it is the magnetic balancing.This circuit mainly consists of electromagnetism conversion component, circuit amplifier and drive compensating circuit.

     

    1 Explanation for type

     

    image001

     

    2 Spec. and size (unit:mm)

     

    2.1 Outline size of AHBC-LTA

    image005 image006

     

    2.2 Outline size of AHBC-LT1005

     

    image009 image010

     

    2.3 Outline size of AHBC-LF

     

    image013 image014

     

    3.Cross-reference tables of spec. -parameter

     

    Specification

    Rated current

    Power supply

    Rated output

    Measuring aperture (mm)

    Precision degree

    AHBC-LTA

    100~300A

    ±15V

    50mA /100mA

    φ 20

    0.5

    AHBC-

    LT1005

    1000A

    ±15V

    200mA

    /

    0.5

    AHBC-LF

    2000A

    ±15V

    400mA

    /

    0.5

    Note: AC and DC input current can be measured, please specify when ordering.

     

    Wiring method

     

    ● Definition of wiring terminals

    206

    Note: 1. Analog output GND must be connected with Power Ground.

    2. Please select the correct current flow direction.

     