Information
Characteristic
1)Communication: RS485/Modbus-Rtu
2)Multi-circuit: A+B independet 2 circuit DC24V output
3)Rated U and I: U:DC48V/240V/336V I:5V
Function
|
|
1. A+B independent two DC lines of voltage, current, power, electric energy,
2. Channel temperature and humidity monitoring
3. 8 Switching status inputs
4. 4 switching status outputs
5. 3 RS485 communications |
|
Installation DIN 35mm
Dimension(L*W*H): 180*90*45 |
|
Appearance



Wiring



Parameter
|
Distribution System |
DC |
|
|
Bus voltage |
Rated voltage |
48VDC,240VDC,336VDC
|
|
Measuring range |
±20% |
|
|
Overload |
Instantaneous voltage 2 times per second
|
|
|
Current incoming circuit |
Rated |
5V(Hall sensor, ±12V powered by AMC100-ZD)
|
|
Overload |
Duration is 1.2 times, instantaneous 10 times/second
|
|
|
Environment
|
Altitude
|
≤2500m
|
|
Temperature |
Operation:-15℃~55℃ Storage:-25℃~70℃
|
|
|
Humidity |
Relative humidity≤93%
|
|
|
Installation
|
Method DIN35mm rail or bottom plate installation
|
|
|
Auxiliary power supply |
AMC100-ZD:Signal power(≤15W) AMC100-ZD-P24:DC 12-24V independent power supply AMC100-ZD-P220: 1、When the constant voltage is DC240V、DC336V,powered by AC220V、 DC240V、DC336V independent supply 2、When the constant voltage is DC48V,powered by DC48V independent supply
|
|
|
Insulation resistance |
The insulation resistance between all terminals and the conductive parts on the shell must be at least 100MΩ
|
|
|
Switch output |
4 channels 3A 250VAC/3A 30VDC |
|
|
Switch input |
8 dry nodes |
|
|
Communication |
1 channel isolatedRS485/Modbus-RTU to the background system 1RS485/Modbus-RTU to touch screen 1RS485/Modbus-RTU connection to the downstream module 1-channel Ethernet communication function is optional
|
|
|
Installation |
DIN35mm rail or bottom plate installation |
|
Quotation
|
Shape |
Type |
Function |
FOB Shang Hai (USD) |
![]() |
AMC100-ZA |
Monitoring the full power parameters of the A+B dual three-phase AC incoming circuit, 8 switching status inputs, 4 switching status outputs, 2 leakage monitoring, 1 temperature and humidity detection, 3 RS485 communications |
148 |
![]() |
AMC-FA30 |
Monitor the full power parameters of a total of 30 branches of A+B dual AC outlets, and 1 RS485 communication |
133 |
![]() |
AMC-FA48 |
Monitor the full power parameters of a total of 48 branches of A+B dual AC outlets, and 1 RS485 communication |
177 |
![]() |
AMC-FAK30 |
Monitor the full power parameters and switch status of a total of 30 branches of A+B dual AC outlets, and 1 RS485 communication |
177 |
![]() |
AMC-FAK48 |
Monitor the full power parameters and switch status of a total of 48 branches of A+B dual AC outlets, and 1 RS485 communication |
237 |
![]() |
AMC100-ZD |
Monitors the voltage, current, power, and electric energy of 2 independent incoming lines A+B,8 switching input, 4 switching output , 1 temperature and humidity detection, and 3 RS485 communications |
148 |
![]() |
AMC100-FD30 |
Monitor the full power parameters of A+B dual DC outgoing lines in A total of 30 branches, and 1 RS485 communication |
133 |
![]() |
AMC-FD48 |
Monitor the full power parameters of A+B dual DC outgoing lines in A total of 48 branches, and 1 RS485 communication |
177 |
![]() |
AMC100-FDK30 |
Monitor the full power parameters and switching status(active) of A+B dual DC outlet 30 branches,and 1 RS485 communication |
177 |
![]() |
AMC100-FDK48 |
Monitor the full power parameters and switching status(active) of A+B dual DC outlet 48 branches, and 1 RS485 communication |
237 |
Hot Tags: Data Center Main Incoming Line Power Meter, China Data Center Main Incoming Line Power Meter manufacturers, suppliers, factory, Single Phase Prepaid Energy Meter, Three Phase Prepaid Energy Meter, DC Power Meter, Wireless 3 Phase Energy Meter, AC Power Meter, Wireless Three Phase AC Energy Meter