Acrel Co., Ltd
+8615000360686
Data Center Main Incoming Line Power Meter

Data Center Main Incoming Line Power Meter

● Designed specifically for the power supply management of server in the data center
● A+B 2 independent DC input cables
● U, I, P, Q, S, PF, kWh, kvarh

Send Inquiry
  • Description

    Information

     

    Characteristic

    1)Communication: RS485/Modbus-Rtu

    2)Multi-circuit: A+B independet 2 circuit DC24V output

    3)Rated U and I: U:DC48V/240V/336V I:5V

     

    Function

     

     

     

     

    product-354-354

    1. A+B independent two DC lines of voltage, current, power, electric energy,

     

    2. Channel temperature and humidity monitoring

     

    3. 8 Switching status inputs

     

    4. 4 switching status outputs

     

    5. 3 RS485 communications

    Installation

    DIN 35mm

     

    Dimension(L*W*H):

    180*90*45

    product-1-1

     

    Appearance

     

    product-1-1
    product-1-1
    product-1-1

     

    Wiring

     

    image015

    image017

    image019

     

     

     

    Parameter

     

    Distribution System

    DC

    Bus voltage

    Rated voltage

    48VDC,240VDC,336VDC

     

    Measuring range

    ±20%

    Overload

    Instantaneous voltage 2 times per second

     

    Current incoming circuit

    Rated

    5V(Hall sensor, ±12V powered by AMC100-ZD)

     

    Overload

    Duration is 1.2 times, instantaneous 10 times/second

     

    Environment

     

    Altitude

     

    ≤2500m

     

    Temperature

    Operation:-15℃~55℃ Storage:-25℃~70℃

     

    Humidity

    Relative humidity≤93%

     

    Installation

     

    Method DIN35mm rail or bottom plate installation

     

    Auxiliary power supply

    AMC100-ZD:Signal power(≤15W)

    AMC100-ZD-P24:DC 12-24V independent power supply

    AMC100-ZD-P220:

    1、When the constant voltage is DC240V、DC336V,powered by AC220V、

    DC240V、DC336V independent supply

    2、When the constant voltage is DC48V,powered by DC48V independent supply

     

    Insulation resistance

    The insulation resistance between all terminals and the conductive parts on the shell must be at least 100MΩ

     

    Switch output

    4 channels 3A 250VAC/3A 30VDC

    Switch input

    8 dry nodes

    Communication

    1 channel isolatedRS485/Modbus-RTU to the background system

    1RS485/Modbus-RTU to touch screen

    1RS485/Modbus-RTU connection to the downstream module

    1-channel Ethernet communication function is optional

     

    Installation

    DIN35mm rail or bottom plate installation

     

    Quotation

     

    Shape

    Type

    Function

    FOB Shang Hai

    (USD)

    product-223-223

    AMC100-ZA

    Monitoring the full power parameters of the A+B dual three-phase AC incoming circuit, 8 switching status inputs, 4 switching status outputs, 2 leakage monitoring, 1 temperature and humidity detection, 3 RS485 communications

    148

    product-224-224

    AMC-FA30

    Monitor the full power parameters of a total of 30 branches of A+B dual AC outlets, and 1 RS485 communication

    133

    product-223-223

    AMC-FA48

    Monitor the full power parameters of a total of 48 branches of A+B dual AC outlets, and 1 RS485 communication

    177

    product-223-223

    AMC-FAK30

    Monitor the full power parameters and switch status of a total of 30 branches of A+B dual AC outlets, and 1 RS485 communication

    177

    product-223-223

    AMC-FAK48

    Monitor the full power parameters and switch status of a total of 48 branches of A+B dual AC outlets, and 1 RS485 communication

    237

    product-223-223

    AMC100-ZD

    Monitors the voltage, current, power, and electric energy of 2 independent incoming lines A+B,8 switching input, 4 switching output , 1 temperature and humidity detection, and 3 RS485 communications

    148

    product-223-223

    AMC100-FD30

    Monitor the full power parameters of A+B dual DC outgoing lines in A total of 30 branches, and 1 RS485 communication

    133

    product-223-223

    AMC-FD48

    Monitor the full power parameters of A+B dual DC outgoing lines in A total of 48 branches, and 1 RS485 communication

    177

    product-223-223

    AMC100-FDK30

    Monitor the full power parameters and switching status(active) of A+B dual DC outlet 30 branches,and 1 RS485 communication

    177

    product-223-223

    AMC100-FDK48

    Monitor the full power parameters and switching status(active) of A+B dual DC outlet 48 branches, and 1 RS485 communication

    237

    Hot Tags: Data Center Main Incoming Line Power Meter, China Data Center Main Incoming Line Power Meter manufacturers, suppliers, factory, Wireless 3 Phase Energy Meter, Single Phase Prepaid Energy Meter, Wireless Three Phase AC Energy Meter, DC Power Meter, wifi energy meter, Three Phase Prepaid Energy Meter

    Previous: AMC100-ZA
    Next: AMC100-FD48

(0/10)

clearall